800KVA 400KV AC Resonance Test System Maka 220 KV GIS

800KVA 400KV AC Resonance Test System Maka 220 KV GIS

Okwu mmalite Ngwa a nwalere na ihe achọrọ 1. 220KV GIS AC voltaji na-anagide ule, ugboro ole ule bụ 30~300Hz, voltaji ule agaghị agafe 395KV, oge nnwale bụ 1min. 2. 110KV GIS AC voltaji na-eguzogide ule, ugboro ule bụ 30~300Hz, voltaji ule agaghị agafe 265KV,
Okwu Mmalite ngwaahịa

 

Ngwa na ihe achọrọ

1. 220KV GIS AC voltaji na-eguzogide ule, ugboro ule bụ 30~300Hz, voltaji ule agaghị agafe 395KV, oge ule bụ 1min.

2. 110KV GIS AC voltaji na-eguzogide ule, ugboro ule bụ 30~300Hz, voltaji ule agaghị agafe 265KV, oge ule bụ 1min.

3. 35KV GIS AC voltaji na-eguzogide ule, ugboro ule bụ 30~300Hz, voltaji ule agaghị agafe 95KV, oge ule bụ 1min.

Ọnọdụ ọrụ

Okpomọkụ gburugburu: -100C –50 0C;

2. iru iru mmiri: Ihe na-erughị ma ọ bụ hà nhata 90% RH

3. elu: Ihe na-erughị ma ọ bụ hà nhata 1000m

Isi teknuzu paramita na ọrụ

ikike ikike: 800kVA;

ike ntinye: 3 nkeji 380V, 50Hz;

gosiri voltaji: 80kV; 160KV, 400KV

akara ugbu a: 10A;4A;2A;

ugboro ọrụ: 30-300Hz;

mmepụta ifegharị: sine ife

Ihe ngbanwe nke waveform Ọnụego mgbanwe nke mmepụta voltaji waveform Ihe na-erughị ma ọ bụ haha ​​na 1%;

oge ọrụ: ibu erughị eru kwere ka ọ na-arụ ọrụ 60min, karịa - voltaji 1.1 ugboro 1min;

Okpomọkụ ịrị elu: ibu na-erughị eru kwere ka ọ na-arụ ọrụ 60min, mgbe okpomọkụ ahụ bilitere Ihe na-erughị ma ọ bụ hà nhata 65K

ihe kacha mma: Q Kariri ma ọ bụ haha ​​30(f=45Hz)

ọrụ nchekwa: karịrị-ugbu a, n'ofe{1} voltaji na nchekwa ọkụ ka a na-enye maka ngwaahịa a nwalere (lee ọkụ ntụgharị ugboro ugboro maka nkọwa).

izi ezi: Sistemu bara uru 1.5;

 

Vidiyo na-arụ ọrụ nyocha AC resonant

 

Usoro ngwaahịa

 

800kVA/400kVbụ imewe 10 reactors, na80kVA/40kV/2A/60Hmaka otu reactor.

Ngwakọta

Nnwale ihe

Reactor 80kVA/40kV*10

Nhọrọ mmepụta ihe ntụgharị mkpali

Ule voltaji (kV)

220KV GIS

jikọọ 10 reactor na usoro

24kV

Ihe na-erughị ma ọ bụ hà nhata 395kV

110 KV GIS

jikọọ 7 reactors na usoro

24KV

Ihe na-erughị ma ọ bụ hà nhata 265kV

35KV GIS

jikọọ 3 reactors na usoro

6KV

Ihe na-erughị ma ọ bụ hà nhata 95kV

 

Sistemu na parameters

na-akpali akpali transformer JLB{0}37kVA/6/12/24kV/0.4kV 1setịpụrụ

ikike ikike:55kVA;

ntinye voltaji: 0-400V, otu oge;

voltaji mmepụta: 6/12/24kV

Ihe owuwu: ụdị akọrọ;

arọ: 180kg;ike ọkọnọ ike ugboro ugboro CHXB-F -37kW/380V 1 setịpụrụ

Enyere ikike mmepụta: 37kW

Ike ọkọnọ maka ịrụ ọrụ: 380± 10% V (otu / 3phase), ugboro ugboro

voltaji mmepụta: 0-400V, otu,

Ntinye aka ugbu a:92.5A

ewepụtara mmepụta ugbu a:92.5A

Mkpebi voltaji: 0.01kV

Izizi nha voltaji: 1.5%

Ugboro ugboro: 30 - 300Hz

Mkpebi njikwa ugboro ugboro: Ihe na-erughị ma ọ bụ haha ​​na 0.1Hz

nkwụsi ike ugboro: 0.1%

Oge ịgba ọsọ: Na-aga n'ihu na ikike elele 5min

Na-aga n'ihu n'ike 5minmax okpomọkụ nke akụrụngwa na-erughị ma ọ bụ haha ​​65K

Ọkwa mkpọtụ: Ihe na-erughị ma ọ bụ haha ​​na 50dB

Enwere ike itinye ọrụ ndị a

A na-edobe ọkụ ọkụ na-agbanwe agbanwe n'ụzọ kwụ ọtọ na kwụ ọtọ, ọ kachasị adabara maka ọrụ ubi na nleba anya.

N'ime na n'èzí nwere ujo pụrụ iche{0}} na-anagide ụkwụ nkwado rọba na igbe aluminom na-echebe, nke nwere ike ibelata ịma jijiji nke ọma n'oge njem yana ujo mgbe a na-ebuli elu. Ekwadoro ogologo oge {{2} nkwụsi ike na ntụkwasị obi nke ọkụ ọkụ ugboro ugboro;

ihe ngosi paramita: Aka ma ọ bụ òké mpụga nnukwu ihuenyo LCD sistemụ. Gosipụta voltaji resonant (voltaji e lekwasịrị anya n'ihu ule), Ugboro ule, ugboro nha, obere-voltaji voltaji, obere-voltaji dị ugbu a, nagide oge voltaji, nchekwa overvoltage, nchebe karịrị, nchekwa ọkụ, nkwalite nzọụkwụ na oge, mgbanwe ọnọdụ ọrụ, ikike, inductance, mgbako mgbanwe ugboro ugboro, ngụkọ ajụjụ ọnụọgụ, nwekwara ike igosipụta. usoro, voltaji usoro na na na-ekpe ozugbo na resonance ugboro ziri ezi na kwụsie ike nke ule.

paramita ntọala: Nnukwu ihuenyo mmetụ LCD agba ihuenyo na mpụta òké ozugbo mezue ntọala nke paramita dị iche iche, nwere ike ịtọ ugboro mmalite, kwụsị ugboro, mmalite voltaji, oge nkwalite na oge, nha nke voltaji divider mgbanwe ratio, excitation mgbanwe ratio, overvoltage nchedo, overcurrent nchebe, flashover nchebe, ule mode, capacitance, na inductance ugboro mgbanwe mgbako, parameter ntọala ndụmọdụ na enyemaka. wdg.

Arọ: Ihe dịka 35kg

HV reactor DK{0}}80kVA/40kV 10 mba

Oke ikike:80kVA;

Ọnụ ọkụ eletrik: 40kV;

Enyere ugbu a:2A;

inductance: 60H / ọs

ihe dị mma:Q karịrị ma ọ bụ haha ​​30 (f=45Hz);

Ọdịdị: ụdị akọrọ;

arọ: ihe dịka 65kg;

capacitive voltaji nkesa FRC-400kV/500pF 1setịpụrụ

Ọnụ ọkụ eletrik: 400kV;

Ike HV: 500pF;

ọnwụ dielectric:tgσ Ihe na-erughị ma ọ bụ hà nhata na 0.5%;

oke nke nkesa voltaji: 6000: 1

nha nha nha nha: uru na-arụ ọrụ 1.5

arọ: ihe dịka 35kg;

 

Njirimara ngwaahịa na ngwa

 

Ndepụta nkwakọ ihe

ndepụta akụrụngwa nhazi

mba

aha

Ụdị na nkọwapụta

otu

Qty

ikwu okwu

1

Ihe ntụgharị na-akpali akpali

JLB-37kVA/6/12/24kV/0.4kV

setịpụrụ

1

 

2

mgbanwe - ọkụ ọkụ ugboro ugboro

CHXB{{0}F-37kW/380V

setịpụrụ

1

 

3

Igwe ọkụ ọkụ dị elu

DK-80kVA/40kV

setịpụrụ

1

 

4

capacitive voltaji nkesa

FRC-400kV/500pF

setịpụrụ

1

 

6

Wiwi njikọ dị n'ime

 

setịpụrụ

1

 

Ndepụta akwụkwọ

Mba

aha

otu

qty

kwuo

1

Ex{{0}Akọ akụkọ nnwale ụlọ ọrụ

oyiri

1

 

2

akwụkwọ ntuziaka

oyiri

1

3

Asambodo ngwaahịa na ndị ahịa

nkọwa kaadị

setịpụrụ

1

 

 

Nkọwapụta
a
 
b
 
c
 
2
 

 

FAQ

 

1. Nnyefe:nnyefe ngwa ngwa na ụdị njem na-agbanwe agbanwe
2. Ụgwọ:Họrọ usoro ịkwụ ụgwọ na ụzọ ịkwụ ụgwọ ị dabara
3. Ọrụ ire ere:Kọntaktị n'ịntanetị nke awa 24, Họrọ ụdị akụrụngwa kwesịrị ekwesị dị ka arịrịọ gị si dị, nye onyinye kacha mma, nkwado nhazi
4. Oge ikike:All igwe mma nkwa maka otu afọ na ndụ ọrụ nkwado maka gị. Nzaghachi n'ịntanetị nye nsogbu teknụzụ ndị ahịa.

 

Line mmepụta

 

 

 

Production

Okwu ule na saịtị
220KV GIS
132KV GIS & 220KG GIS ule
230KV GIS
230KV GIS ule
400KV GIS
Nnwale 400KV GIS
transformer
Nnwale ntụgharị
cable
Nnwale eriri
switchgear
Nnwale 400KV GIS
Nnwale Switchgear

 

Nleta ndị ahịa

customer visit

Asambodo anyị

 

Certificates -2

Ihe nchịkọta dị ọkụ: Sistemụ ule 800kva 400kv ac resonance maka 220 kv gis, China 800kva 400kv ac resonance test system maka ndị na-emepụta 220 kv gis, ndị na-ebu, ụlọ ọrụ

Zipu ozi